Current/Voltage Transducer Monitors

Results: 653
Manufacturer
AMBOCarlo Gavazzi Inc.CR Magnetics Inc.Littelfuse Inc.Phoenix ContactSchneider ElectricVerivolt LLCWAGO CorporationWeidmüller
Series
-*CPT-DINCR4500CR4600CR4800CR5300CR6200DCSAE83Entube DEEntube DE-HB
Packaging
BagBoxBulkTray
Product Status
ActiveLast Time BuyObsolete
Type
AC Voltage TransducerAverage RMS AC Voltage TransducerCurrent TransducerDC Voltage TransducerTrue RMS AC Voltage TransducerVoltage Transducer
Input Range
0 ~ 100A0 ~ 10A0 ~ 11A0 ~ 12A0 ~ 150A0 ~ 150VAC0 ~ 15A0 ~ 200A0 ~ 200VDC0 ~ 20A0 ~ 20mA0 ~ 20VAC
Output
0 ~ 10VDC0 ~ 10VDC, 0 ~ 20mA0 ~ 20mA0 ~ 5VDC0 ~ 7VAC0.08 ~ 6A±200mV0.2 ~ 3A0.4 ~ 3.5A±1V1 ~ 10A±2V
Isolation
300VAC (Working), 3500VAC (Test)300VAC (Working), 4000VAC (Test)440VAC (Working), 3300VAC (Test)660VAC (Working), 1500VAC (Test)1200V (Working)1500V (Working)2500V (Working)2500VDC3000VAC (Test)4000VAC (Test)5000V (Working)5000VAC (Test)5300VAC (Test)-
Response Time
8ns20ns1µs2.8µs3µs5µs0.5ms12ms16ms40ms40ms, 330ms70ms
Accuracy
±0.1%±0.2%±0.25%±0.5%0.5%±0.7%1%±2%±5%-
Voltage - Supply
2 ~ 28VDC8 ~ 28V8 ~ 28VDC9 ~ 28VDC10 ~ 30VDC10 ~ 40VDC12 ~ 28VDC13 ~ 30VDC18 ~ 27VAC/DC18.5 ~ 30.2VDC19.2 ~ 253VAC/DC20 ~ 30VDC24VDC85 ~ 264VAC
Mounting Type
-Chassis MountChassis Mount, DIN RailDIN RailFree Hanging (In-Line)Socketable
Termination Style
BNCBNC, SHVBNC, Spring TerminalPlug InQuick Connect - 0.250" (6.3mm)RJ45, Spring TerminalScrew TerminalScrew Terminal, Spring TerminalSpring Terminal
Operating Temperature
-40°C ~ 65°C-35°C ~ 70°C-30°C ~ 60°C-25°C ~ 40°C-25°C ~ 50°C-25°C ~ 60°C-25°C ~ 65°C-25°C ~ 70°C-25°C ~ 80°C-20°C ~ 50°C-20°C ~ 60°C-20°C ~ 65°C-10°C ~ 60°C-5°C ~ 55°C
Approval Agency
-ATEX, cULusATEX, EACCECE, CSA, cURusCE, CSA, ULCE, cULusCE, cURusCE, cURus, ULCE, ULCSA, EAC, ULVDE
Stocking Options
Environmental Options
Media
Marketplace Product
653Results

Showing
of 653
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (6A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
26
In Stock
1 : 108 931,94000 Ft
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2308027
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
29
In Stock
133
Factory
1 : 131 387,35000 Ft
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
IsoBlock V-1C
ISOBLOCK V-1C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
128
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
86
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±1500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
CR4510-250,CR4510-500
CR4510-250
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
22
In Stock
1 : 93 831,10000 Ft
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 250VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
CR4510-500
CR4510-500
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
6
In Stock
1 : 93 831,10000 Ft
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 500VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (50A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
17
In Stock
1 : 108 931,94000 Ft
Box
Box
Active
Current Transducer
0 ~ 50A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Screw Terminal, Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
8
In Stock
1 : 108 931,94000 Ft
Box
Box
Active
Current Transducer
0 ~ 25A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2308027
2308108
TRANSDUCER CURRENT 24VDC
Phoenix Contact
18
In Stock
1 : 126 363,97000 Ft
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
0 ~ 10VDC
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
2308027
2308030
TRANSDUCER CURRENT 24VDC
Phoenix Contact
12
In Stock
1 : 131 387,35000 Ft
Bulk
Bulk
Active
Current Transducer
0 ~ 200A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
2810625
2810625
TRANSDUCER CURR 19.2-253VAC/DC
Phoenix Contact
6
In Stock
1 : 145 750,82000 Ft
Bulk
Bulk
Active
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
200ms
-
19.2 ~ 253VAC/DC
DIN Rail
Screw Terminal
-20°C ~ 65°C
ATEX, cULus
IsoBlock V-1C
ISOBLOCK V-1C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
19
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±300V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (100V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
19
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±100V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
17
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
8 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (50V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
15
In Stock
1 : 165 037,81000 Ft
Box
Box
Active
Voltage Transducer
±50V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (1000V 5V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
15
In Stock
1 : 173 709,66000 Ft
Box
Box
Active
Voltage Transducer
±1000V
±5V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2906242
2906242
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
11
In Stock
76
Factory
1 : 179 489,61000 Ft
Bulk
Bulk
Active
Voltage Transducer
±660VDC
±10V
5300VAC (Test)
16ms
-
24VDC
DIN Rail
Screw Terminal
-25°C ~ 60°C
CE, cULus
IsoBlock I-FG-4C
ISOBLOCK I-FG-4C (6A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
10
In Stock
1 : 343 102,59000 Ft
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-4C
ISOBLOCK I-FG-4C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
8
In Stock
1 : 343 102,59000 Ft
Box
Box
Active
Current Transducer
0 ~ 25A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-4C
ISOBLOCK I-FG-4C (15A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
2
In Stock
1 : 343 102,59000 Ft
Box
Box
Active
Current Transducer
0 ~ 15A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-4C
ISOBLOCK V-4C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
13
In Stock
1 : 511 884,88000 Ft
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-4C
ISOBLOCK V-4C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
8
In Stock
1 : 511 884,88000 Ft
Box
Box
Active
Voltage Transducer
±300V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-4C
ISOBLOCK V-4C (500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
7
In Stock
1 : 511 884,88000 Ft
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-4C
ISOBLOCK V-4C (100V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
3
In Stock
1 : 511 884,88000 Ft
Box
Box
Active
Voltage Transducer
±100V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
CR4620,CR4510,CR4810,CR4820 Parts
CR4620-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
10
In Stock
1 : 54 627,27000 Ft
Box
Box
Active
Average RMS AC Voltage Transducer
0 ~ 150VAC
4 ~ 20mA
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
Showing
of 653

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.